# -*- coding: utf-8 -*- # Generated by the protocol buffer compiler. DO NOT EDIT! # source: message.proto """Generated protocol buffer code.""" from google.protobuf.internal import enum_type_wrapper from google.protobuf import descriptor as _descriptor from google.protobuf import descriptor_pool as _descriptor_pool from google.protobuf import message as _message from google.protobuf import reflection as _reflection from google.protobuf import symbol_database as _symbol_database # @@protoc_insertion_point(imports) _sym_db = _symbol_database.Default() DESCRIPTOR = _descriptor_pool.Default().AddSerializedFile(b'\n\rmessage.proto\"\xb9\x01\n\x0cmeasure_info\x12\n\n\x02\x63x\x18\x01 \x01(\x02\x12\n\n\x02\x63y\x18\x02 \x01(\x02\x12\r\n\x05theta\x18\x03 \x01(\x02\x12\x0e\n\x06length\x18\x04 \x01(\x02\x12\r\n\x05width\x18\x05 \x01(\x02\x12\x0e\n\x06height\x18\x06 \x01(\x02\x12\x11\n\twheelbase\x18\x07 \x01(\x02\x12\x13\n\x0b\x66ront_theta\x18\x08 \x01(\x02\x12\x14\n\x0c\x62order_statu\x18\t \x01(\x05\x12\x15\n\rground_status\x18\n \x01(\x05\"M\n\x0eparkspace_info\x12\n\n\x02id\x18\x01 \x01(\x05\x12\x0f\n\x07unit_id\x18\x02 \x01(\x05\x12\r\n\x05\x66loor\x18\x03 \x01(\x05\x12\x0f\n\x07room_id\x18\x04 \x01(\x05\"G\n\x0btable_statu\x12\x1d\n\rexecute_statu\x18\x01 \x01(\x0e\x32\x06.STATU\x12\x19\n\x11statu_description\x18\x02 \x01(\t\"\xc3\x02\n\npark_table\x12\x1b\n\x05statu\x18\x01 \x01(\x0b\x32\x0c.table_statu\x12\x10\n\x08queue_id\x18\x02 \x01(\x05\x12\x12\n\ncar_number\x18\x03 \x01(\t\x12\x0f\n\x07unit_id\x18\x04 \x01(\x05\x12\x13\n\x0bterminal_id\x18\x05 \x01(\x05\x12\x13\n\x0bprimary_key\x18\x06 \x01(\t\x12,\n\x15\x65ntrance_measure_info\x18\x07 \x01(\x0b\x32\r.measure_info\x12-\n\x14\x61llocated_space_info\x18\x08 \x01(\x0b\x32\x0f.parkspace_info\x12,\n\x15\x61\x63tually_measure_info\x18\t \x01(\x0b\x32\r.measure_info\x12,\n\x13\x61\x63tually_space_info\x18\n \x01(\x0b\x32\x0f.parkspace_info\"\x8c\x02\n\npick_table\x12\x1b\n\x05statu\x18\x01 \x01(\x0b\x32\x0c.table_statu\x12\x10\n\x08queue_id\x18\x02 \x01(\x05\x12\x12\n\ncar_number\x18\x03 \x01(\t\x12\x0f\n\x07unit_id\x18\x04 \x01(\x05\x12\x13\n\x0bterminal_id\x18\x05 \x01(\x05\x12\x13\n\x0bprimary_key\x18\x06 \x01(\t\x12,\n\x13\x61\x63tually_space_info\x18\x07 \x01(\x0b\x32\x0f.parkspace_info\x12,\n\x15\x61\x63tually_measure_info\x18\x08 \x01(\x0b\x32\r.measure_info\x12\x11\n\texport_id\x18\t \x01(\x05\x12\x11\n\tis_leaved\x18\n \x01(\x08\"<\n\x0eout_mcpu_statu\x12\x12\n\ndoor_statu\x18\x01 \x01(\x05\x12\x16\n\x0eoutside_safety\x18\x02 \x01(\x05\"X\n\rin_mcpu_statu\x12\x12\n\ndoor_statu\x18\x01 \x01(\x05\x12\x0f\n\x07\x62\x61\x63k_io\x18\x02 \x01(\x05\x12\x11\n\tis_occupy\x18\x03 \x01(\x05\x12\x0f\n\x07heighth\x18\x04 \x01(\x05\",\n\rmeasure_statu\x12\x1b\n\x04info\x18\x01 \x01(\x0b\x32\r.measure_info\"e\n\x14\x64ispatch_region_info\x12\x13\n\x0bterminal_id\x18\x01 \x01(\x05\x12\x1b\n\x13turnplate_angle_min\x18\x02 \x01(\x02\x12\x1b\n\x13turnplate_angle_max\x18\x03 \x01(\x02\"\x99\x02\n\x13\x64ispatch_node_statu\x12\x1c\n\x05statu\x18\x01 \x01(\x0e\x32\r.CarrierStatu\x12\x17\n\x0fidle_stop_floor\x18\x02 \x01(\x05\x12&\n\x11running_pack_info\x18\x03 \x01(\x0b\x32\x0b.park_table\x12&\n\x11running_pick_info\x18\x04 \x01(\x0b\x32\x0b.pick_table\x12\x0f\n\x07unit_id\x18\x05 \x01(\x05\x12\x15\n\rplc_heartbeat\x18\x06 \x01(\x05\x12\x17\n\x0fplc_status_info\x18\x07 \x01(\x05\x12:\n\x1b\x64ispatch_region_info_vector\x18\x08 \x03(\x0b\x32\x15.dispatch_region_info\">\n\x13terminal_node_statu\x12\x13\n\x0bterminal_id\x18\x01 \x01(\x05\x12\x12\n\ncar_number\x18\x02 \x01(\t* \n\x05STATU\x12\x0b\n\x07\x65Normal\x10\x00\x12\n\n\x06\x65\x45rror\x10\x01*0\n\x0c\x43\x61rrierStatu\x12\t\n\x05\x65Idle\x10\x00\x12\t\n\x05\x65\x42usy\x10\x01\x12\n\n\x06\x65\x46\x61ult\x10\x02\x62\x06proto3') _STATU = DESCRIPTOR.enum_types_by_name['STATU'] STATU = enum_type_wrapper.EnumTypeWrapper(_STATU) _CARRIERSTATU = DESCRIPTOR.enum_types_by_name['CarrierStatu'] CarrierStatu = enum_type_wrapper.EnumTypeWrapper(_CARRIERSTATU) eNormal = 0 eError = 1 eIdle = 0 eBusy = 1 eFault = 2 _MEASURE_INFO = DESCRIPTOR.message_types_by_name['measure_info'] _PARKSPACE_INFO = DESCRIPTOR.message_types_by_name['parkspace_info'] _TABLE_STATU = DESCRIPTOR.message_types_by_name['table_statu'] _PARK_TABLE = DESCRIPTOR.message_types_by_name['park_table'] _PICK_TABLE = DESCRIPTOR.message_types_by_name['pick_table'] _OUT_MCPU_STATU = DESCRIPTOR.message_types_by_name['out_mcpu_statu'] _IN_MCPU_STATU = DESCRIPTOR.message_types_by_name['in_mcpu_statu'] _MEASURE_STATU = DESCRIPTOR.message_types_by_name['measure_statu'] _DISPATCH_REGION_INFO = DESCRIPTOR.message_types_by_name['dispatch_region_info'] _DISPATCH_NODE_STATU = DESCRIPTOR.message_types_by_name['dispatch_node_statu'] _TERMINAL_NODE_STATU = DESCRIPTOR.message_types_by_name['terminal_node_statu'] measure_info = _reflection.GeneratedProtocolMessageType('measure_info', (_message.Message,), { 'DESCRIPTOR' : _MEASURE_INFO, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:measure_info) }) _sym_db.RegisterMessage(measure_info) parkspace_info = _reflection.GeneratedProtocolMessageType('parkspace_info', (_message.Message,), { 'DESCRIPTOR' : _PARKSPACE_INFO, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:parkspace_info) }) _sym_db.RegisterMessage(parkspace_info) table_statu = _reflection.GeneratedProtocolMessageType('table_statu', (_message.Message,), { 'DESCRIPTOR' : _TABLE_STATU, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:table_statu) }) _sym_db.RegisterMessage(table_statu) park_table = _reflection.GeneratedProtocolMessageType('park_table', (_message.Message,), { 'DESCRIPTOR' : _PARK_TABLE, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:park_table) }) _sym_db.RegisterMessage(park_table) pick_table = _reflection.GeneratedProtocolMessageType('pick_table', (_message.Message,), { 'DESCRIPTOR' : _PICK_TABLE, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:pick_table) }) _sym_db.RegisterMessage(pick_table) out_mcpu_statu = _reflection.GeneratedProtocolMessageType('out_mcpu_statu', (_message.Message,), { 'DESCRIPTOR' : _OUT_MCPU_STATU, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:out_mcpu_statu) }) _sym_db.RegisterMessage(out_mcpu_statu) in_mcpu_statu = _reflection.GeneratedProtocolMessageType('in_mcpu_statu', (_message.Message,), { 'DESCRIPTOR' : _IN_MCPU_STATU, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:in_mcpu_statu) }) _sym_db.RegisterMessage(in_mcpu_statu) measure_statu = _reflection.GeneratedProtocolMessageType('measure_statu', (_message.Message,), { 'DESCRIPTOR' : _MEASURE_STATU, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:measure_statu) }) _sym_db.RegisterMessage(measure_statu) dispatch_region_info = _reflection.GeneratedProtocolMessageType('dispatch_region_info', (_message.Message,), { 'DESCRIPTOR' : _DISPATCH_REGION_INFO, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:dispatch_region_info) }) _sym_db.RegisterMessage(dispatch_region_info) dispatch_node_statu = _reflection.GeneratedProtocolMessageType('dispatch_node_statu', (_message.Message,), { 'DESCRIPTOR' : _DISPATCH_NODE_STATU, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:dispatch_node_statu) }) _sym_db.RegisterMessage(dispatch_node_statu) terminal_node_statu = _reflection.GeneratedProtocolMessageType('terminal_node_statu', (_message.Message,), { 'DESCRIPTOR' : _TERMINAL_NODE_STATU, '__module__' : 'message_pb2' # @@protoc_insertion_point(class_scope:terminal_node_statu) }) _sym_db.RegisterMessage(terminal_node_statu) if _descriptor._USE_C_DESCRIPTORS == False: DESCRIPTOR._options = None _STATU._serialized_start=1603 _STATU._serialized_end=1635 _CARRIERSTATU._serialized_start=1637 _CARRIERSTATU._serialized_end=1685 _MEASURE_INFO._serialized_start=18 _MEASURE_INFO._serialized_end=203 _PARKSPACE_INFO._serialized_start=205 _PARKSPACE_INFO._serialized_end=282 _TABLE_STATU._serialized_start=284 _TABLE_STATU._serialized_end=355 _PARK_TABLE._serialized_start=358 _PARK_TABLE._serialized_end=681 _PICK_TABLE._serialized_start=684 _PICK_TABLE._serialized_end=952 _OUT_MCPU_STATU._serialized_start=954 _OUT_MCPU_STATU._serialized_end=1014 _IN_MCPU_STATU._serialized_start=1016 _IN_MCPU_STATU._serialized_end=1104 _MEASURE_STATU._serialized_start=1106 _MEASURE_STATU._serialized_end=1150 _DISPATCH_REGION_INFO._serialized_start=1152 _DISPATCH_REGION_INFO._serialized_end=1253 _DISPATCH_NODE_STATU._serialized_start=1256 _DISPATCH_NODE_STATU._serialized_end=1537 _TERMINAL_NODE_STATU._serialized_start=1539 _TERMINAL_NODE_STATU._serialized_end=1601 # @@protoc_insertion_point(module_scope)